TS 700 34% offers a thin, lightweight, laminated film, designed for solar reflection, thermal control and high visibility. Its subtle profile and neutral coloration makes it the ideal material for simple, clean and effective window treatments in all settings.

Fabric Density Semi Transparent Pattern Round – 225 holes per sq. inch. .046 / .070
Openness 34% Greenguard Compliant Yes
Composition Polyester Anti-Static Yes
Color White/Grey Cutting Cold
Thickness .008 in (0.2mm) Seaming Adhesive
Weight 4.67 oz. Sq.Yd PVC-free Yes
Width 60 inches Railroadable Yes
Flame Retardancy NFPA 701-2004
Suitable Products Roller Blinds Hanging Panels Direct Application
thermshade setion header
ThermeShade solar / thermal /optical properties data table

The fabric performance tests were conducted in accordance with ASTM E891 & ASTM E903-96: Total Solar Transmittance (Ts), Total Solar Reflectance (Rs), Solar Reflectance in Infrared (Rs IR), Total Solar Absorptance (As), Visible Reflectance (Rv), and Visible Transmission (Tv). Glass performance tests for Solar Heat Gain Coefficient (SHGC) were conducted using the Lawrence Berkeley National Laboratory Window 7.5 NFRC certified software. SHGC for residential applications is based on a default residential glass makeup of 3mm clear glass / 1/2″ air / 3mm clear glass. Results for SHGC were obtained using the center of glass.

WINDOW 7.5 Vistar Energy / ASTM Courtesy Mermet USA June 2022

thermshade setion header

ASTM E891 & E903-96

TS 700 34% OF RsIR Rs Rs-dif As Ts Ts-dif Rv Rv-dif Tv Tv-dif
ThermēShade-Room 31.62 52.3 49.12 46.9 18.98 31.9 1.48 47.18 45.68 32.27 1.45
ThermēShade-Street 31.62 51.74 52.64 52.21 12.42 34.94 3.27 54.2 53.89 35.17 3.24

ASTM E891: Tables for Terrestrial Direct Normal Solar Spectral Irradiance Tables for Air Mass 1.5
ASTM E891 covers the calculations for the values Rs, As, Ts, Rv, Tv, and Rs IR. The standard uses established solar spectral irradiance distribution tables to calculate the overall fenestration values from the measurements taken using ASTM E903.

ASTM E903: Standard Test Method for Solar Absorbent, Reflectance, and Transmittance of Materials using Integrating Spheres
ASTM E891 covers the calculations for the values Rs, As, Ts, Rv, Tv, and Rs IR. The standard uses established solar spectral irradiance distribution tables to calculate the overall fenestration values from the measurements taken using ASTM E903.

Courtesy Mermet USA June 2022

thermshade setion header

Comparative Analysis Window 7.5

TS 700 34% U – factor Percent Improvement
in Insulation
SHGC Percent Improvement
in Solar Heat
Rejection
Visual
Transmission
Base Window 0.484 0.689 0.72
Base Window + ThermēShade (34%) 0.41 15.3% 0.383 44% 0.291
Base Window Type Width inches Height inches
ID 12 Std Size – Wood + ID 102 Double Glazing Fixed (picture) 47.24 59.06

Complex Glazing Database: ID 18000
NFRC 100: Procedure for Determining fenestration Product U-factors
NFRC 200: Procedure for Determining Fenestration Product Solar Heat Gain Coefficient and Visible Transmittance at Normal Incidence

Vistar Energy Consulting

thermshade setion header

AERC 1 / AERC 2 / AERC 1.3

Simulated File
Name
CGDB
ID
System
Shading type
AERC
Baseline
Window
U-factor
Btu/hr2/F
SHGC VT EPc
ThermēShade
TS 700
18000 Perforated
Screen
BW-B 0.395 0.448 0.409 26

Test Results:
Results with Shades Fully Closed for U–factor, SHGC, and VT, EP results are based on annual performance of shades fully closed and half-open for the cities of Minneapolis and Houston. See AERC 2 for more information about EP ratings
Software Used: Berkeley Lab WINDOW 7.8.28
THERM 7.8.16
AERCalc 1.3.9

Peak Amplitude Consulting LLC

thermshade setion header
SMUD study results table

*42% of daily data included.
Savings/energy use calculations limited to office hours only.

Full Study

thermshade setion header
Room 205 – ThermēShade Average Ambient Temp. 84º
Room 207 – No Shade October, Northern CA
Summer Hotel Study Comparative Data - Room 205

— Temp. ºF
— RH %
— Intensity. lum/ft2
— Current. Amps

Summer Hotel Study Comparative Data - Room 207